Something you should know about laser cutter-Ivy

Something you should know about laser cutter

Advantages of IPG laser source?

1.High photoelectric conversion rate
Can reach 45%, other brands are only about 25%

2.German brand ,good quality,laser power weakened slower than other brand.

3.High market share, a certain degree of reaction to brand strength and quality

4.low failure rate, only 3%,light power can be seen in real time

5.after-sale service spots all over the world, problems can be resolved in time

Function of water-chiller?

Cooling the laser source and cutting head, maintain normal temperature to ensure the normal operation of the fiber laser cutting machine, to ensure the best cutting effect.

Water pipe

We are using to different colors for the water chiller’s pipe, orange pipe means water go inside; blue pipe means water go outside. Two different color can help you recognize easily if you need fix some parts by yourself.

proportional value

Using for adjusting air pressure, mainly controlling oxygen, small pressure when you punch the whole, atmospheric pressure for cutting work.

It can help you just change the gas in the software, no need to find the gas tank.

Running cost

Compared with other cutting equipment, the running cost of fiber laser cutter should be lowest.
The running cost includes 3 parts: electric power, auxiliary gas and spare parts.

1. Electric power  
1kw IPG 6060 model fiber laser cutter rated power about 17kw.
​Real machine running cost occupy 60%~70% of whole power, so the real electric power cost is 10.2~11.9kw/h.

2. Auxiliary gas consumption
One gas tank is 40L in China.

1). Nitrogen consumption is the same for different thickness stainless steel and aluminum.
Its consumption of continue cutting is about 20~30min/tank.

2). Oxygen consumption will decline when carbon steel thickness increase.
The thicker the carbon steel, the less the gas consumption.
For example, 1mm carbon steel cutting gas consumption is about 50~60min/tank.
10mm carbon steel cutting gas consumption is about several hours/tank.

We recommend you use liquid gas, its cost will be much lower. Most of our customers use it.

3. Quick wear parts
Main quick wear parts include nozzle and protective lens.
First year their consumption is about 20~30 pieces, but the cost will decline later.
As their consumption have big relationship with workers’ operation.

whatsapp:0086 17864184107